4. Check safety circuits for proper operation.
5. Check refrigeration system (see page12 12).
6. Check unit for abnormal noise. Tighten machine and cabinet screws, if necessary.
7. Check white upper bearings on auger assembly. If bearings are less than 1/16Ȃ thick, replace. See Figure 5
REPLACE
OK
REPLACE
1/16Ȃ
OK
1/16Ȃ
FIGURE 5. UPPER BEARING AND AUGER ASSEMBLY
NOTE: preventive maintenance can increase the trouble–free life of your ice maker. Failure to perform
preventive maintenance could void your equipment warranty