5. Remove four screws from bottom of valve.
6. Pull off bottom of valve
and center section.
7. Rebuild the valve and reassemble. Be sure the cam-lock washer is in the groove of
the syrup line.
NOTE: O-rings should be lubricated with sanitary lubricant.
NOTE: Red O-ring at bottom of valve plate must be a tear resistant teflon.
Use p/n 31525064.