Cornelius Quantum 1000 Informazioni Techniche Pagina 15

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 32
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 14
Wilshire Juice Training Manual
© 1999, IMI Cornelius Inc. - 9 -
4.3 SLJ Valve Mixing Block Rebuilding:
Valves should be rebuilt if they are leaking. Cornelius supplies all the parts necessary for
rebuilding.
1. Loosen cam lock-washer on
both water lines.
2. Remove two screws on the
bottom of the plate.
Loosen cam
lock-washer
cam lock-
washers
Screws