Trouble Probable Cause Remedy
NOTE: If water supply is dirty, be sure to flush lines and carbonator completely. It may be neces-
sary to remove lines to carbonator tank. Flush tank and all inlet lines to remove any foreign par-
ticles or dirt.
NO PRODUCT DIS-
PENSED FROM ONE
DISPENSING VALVE
A. Broken or disconnected wiring.
B. Inoperative dispensing valve sole-
noid coil.
C. Inoperative dispensing valve
micro switch.
A. Repair or connect wiring.
B. Replace solenoid coil as
instructed.
C. Replace micro switch as
instructed.
ONLY CARBONATED
WATER DISPENSED.
A. Quick disconnects not secure on
syrup tanks.
B. Out of syrup.
C. B-I-B connectors not properly
connected.
D. Syrup secondary CO
2
regulator
not properly adjusted.
E. Inoperable dispensing valve.
F. Dispensing valve syrup flow regu-
lator not properly adjusted.
G. Dispensing valve syrup flow regu-
lator, syrup tank quick disconnect,
or syrup lines restricted.
A. Secure quick disconnects on
syrup tanks.
B. Replenish syrup supply as
instructed.
C. Properly attach the connectors.
D. Adjust syrup tanks secondary
CO
2
regulator as instructed.
E. Repair dispensing valve.
F. Adjust dispensing valve syrup
flow regulator (Water-to Syrup
Ratio) as instructed.
G. Sanitize syrup system as
instructed.
ONLY SYRUP DIS-
PENSED
A. Plain water inlet supply line shut-
off valve closed.
B. Carbonator power cord
unplugged from electrical outlet.
A. Open plain water inlet supply line
shutoff valve.
B. Plug carbonator power cord into
electrical outlet.
TROUBLESHOOTING for Carbonator
Trouble Probable Cause Remedy
PUMP MOTOR WILL
NOT RUN
A. Locked pump rotor-dirt or pipe
compound in pump; pump seized.
B. Carbonator flooded.
C. No power.
A. Remove and check for free rota-
tion or replace. Also check CO
2
supply, faulty single check valve,
liquid level control or probe.
B. Main water supply pressure
higher than CO
2
pressure within
the carbonator. If maximum water
supply pressure is within 20 PSI
of CO
2
pressure, install water
pressure regulator.
C. Check source of electrical supply
and for loose connections.
Vedere la pagina 32