IntelliCarb Drop-In Ice Cooled Installation Guide
© 2003-2005, IMI Cornelius Inc. - 5 - Publication Number: 630460204INS
INSTALLATION
CAUTION Only trained and certified electrical, plumbing and refrigeration technicians should
service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL
CODES.
INSTALLATION REQUIREMENTS
Requirements Summary
Weight:...................................................counter must be level and able to support 450 lbs.
Environment:..................................................................................... indoor installation only
Temperature:................................................................... 40 to 100° F ambient temperature
CO
2
:................................................................................................................. 75 psi at unit
Syrup: ....................................................................... 60 psi. min,.70 .75 ounces per sec.,
...............................not to exceed 3.75 oz/sec Finished Product Flow Rate (.6 gpm) at unit
Water pressure: ....................................................................................60 psi max. at pump
Electrical: ..................................................................................................... see name plate
Water volume........................................................................................................... 125 gph
Product supply beverage tubing ............................................................................ .375 min.