IntelliCarb Drop-In Ice Cooled Installation Guide
© 2003-2005, IMI Cornelius Inc. - 31 - Publication Number: 630460204INS
VALVE DELIVERS CO
2
GAS CONTINUOUSLY
A. Pump motor will not run.
B. Pump water supply restricted.
C. Relief valve venting.
D. Worn pump.
A. See
PUMP MOTOR WILL NOT
RUN.
B. Clean strainer. Check for faulty
double check valve.
C. Repair or replace.
D. See
PUMP MOTOR WILL NOT
STOP
.
VALVE DELIVERS SODA
WATER AND CO
2
GAS
INTERMITTENLY
A. Pump water supply restricted.
B. Relief valve venting.
C. Inefficient or worn pump.
A. Clean strainer. Check for faulty
single check valve, clogged water
filter, water supply off or blocked,
ruptured tank, faulty liquid level
control or double check valve.
B. Replace or repair.
C. See
PUMP MOTOR WILL NOT
STOP
.
POOR CARBONATION A. Flooded carbonator.
B. Water temperature too high
(warm).
C. Oil in water supply.
D. Supply water containing too much
air in solution.
E. Poor quality paper cups.
F. Dirty or greasy glassware.
G. Excessive foam.
H. Flat drinks.
A. See
PUMP MOTOR WILL NOT
RUN.
B. Check water inlet temperature.
Lower temperature provides bet-
ter carbonation.
C. Check pipe thread compound.
Remove and clean and replace
with teflon pipe thread tape.
D. To remove air before it enters
pump, it will be necessary to
install an open tank with float to
control water level.
E. Purchase quality cups made for
this application.
F. Wash all glassware.
G. CO
2
BIB pump pressure too high,
contamination within the bever-
age system, poor quality paper
cups or dirty glassware.
H. Draw drinks against side of glass
or cup. Check for insufficient CO
2
contamination, bad check valve,
ruptured CO
2
line
TROUBLESHOOTING for Carbonator
Trouble Probable Cause Remedy